Straight answers to common questions.

What we do, what the regulations require, and how to get started. Don’t see your question? Call 718.865.3779.

No matching questions. Try a different word, or ask us directly.

About Mainstream

What does Mainstream take care of?

Your plumbing compliance, start to finish:

  • Identifying which requirements apply to each property, and when they’re due
  • Scheduling inspections and tests
  • Arranging access with your building staff
  • Reports, certifications and filings
  • Keeping the next cycle on the calendar
Is Mainstream affiliated with the Department of Buildings?

No. Mainstream is a private company. We are not affiliated with or endorsed by the NYC Department of Buildings, the Department of Environmental Protection or any government agency. We work with agency requirements every day; we don’t speak for the agencies.

Do you work with property management companies, or individual owners?

Both. Management firms use us to manage compliance across portfolios with a single point of contact. Owners and landlords use us to handle what their building needs, from start to finish.

How is pricing structured?

It depends on the service and the property. For all services, we’ll provide a quote after reviewing your building’s requirements.

Local Law 152 gas inspections

How do I know when my building is due?

Inspections follow a four-year cycle set by community district. Buildings in Community Districts 4, 6, 8, 9 and 16 are due in 2026; Districts 11, 12, 14, 15 and 17 are due in 2027. See the full schedule, or send us the address and we’ll confirm it.

Are one- and two-family homes exempt?

Yes. Buildings classified in occupancy group R-3 — one- and two-family dwellings — are exempt from Local Law 152. Note that Local Law 157 gas detector requirements may still apply to non-owner-occupied one- and two-family homes.

What’s the penalty for missing the deadline?

Failure to file the required certification can result in a civil penalty of $5,000, or $1,500 for three-family buildings. Resolving the violation requires both paying the penalty and filing the certification.

What happens if the inspection finds a problem?

Conditions that need correction must be repaired by a Licensed Master Plumber and the corrections certified to DOB within the timeframes DOB sets. Unsafe conditions, such as a gas leak, are reported immediately to the gas utility, DOB and the building owner. Mainstream takes care of the follow-up and tracks it to completion.

How are certifications filed now?

As of July 27, 2026, Local Law 152 certifications, extension requests and related submissions are filed through DOB NOW: Safety, and filing fees apply.

Local Law 157 gas detectors

When must natural gas alarms be installed?

By January 1, 2027. The Department of Buildings confirmed the deadline in a June 2026 service notice.

Which buildings are covered?

Generally, residential buildings with gas service: multifamily buildings (Class A and Class B multiple dwellings) and one- and two-family homes that are not owner-occupied. Buildings without gas piping or gas service are exempt.

What kind of detector is required?

Natural gas alarms listed and labeled to UL 1484, the safety standard for residential gas detectors. Mainstream offers approved detectors at competitive pricing.

Backflow

What is backflow?

Backflow is the unwanted reversal of water flow in a plumbing system. It can draw contaminated water back into the drinking water supply — which is why NYC requires prevention devices where the risk exists.

How often must a backflow device be tested?

At installation, and every 12 months after. Tests must be performed by a New York State–certified backflow prevention tester, and the report submitted to DEP. Missing an annual test can result in fines or disconnection of water service.

How do I know if my property needs a backflow preventer?

DEP requires devices on properties that pose a hazard to the water supply — common examples include buildings with treated-water boilers, roof tanks, commercial kitchens, irrigation systems or pools. If you’ve received a DEP notice, or aren’t sure, we’ll review your property and arrange an evaluation.

What if a device fails its test?

The device must be repaired or replaced and retested. Mainstream takes care of the repair, the retest and the updated filing.

Boilers & filings

Does my boiler need an annual inspection?

Most boilers in residential buildings with six or more units, and in commercial buildings, must be inspected every calendar year with the report filed with DOB. Late filing carries a penalty of $50 per month per boiler, up to $600; failure to file carries a $1,000 penalty per boiler.

What is an OP-49 filing?

It’s the notification that tells DOB a boiler has been removed or permanently disconnected — now filed as a Boiler Removal Notification in DOB NOW: Build by a licensed professional, generally within 30 days. Without it, DOB may still expect inspections for a boiler that’s gone.

What is a DEP CATS filing?

CATS is the NYC Department of Environmental Protection’s Clean Air Tracking System, where boiler registrations and air permits are filed and renewed. Boilers from 350,000 BTU per hour up to 4.2 million BTU per hour need a DEP registration; larger boilers need a work permit and a certificate of operation. Registrations and certificates are renewed every three years, separately from DOB boiler inspections. We file and renew them for you.

What is an LAA?

A Limited Alteration Application — a DOB filing for qualifying minor plumbing work, filed in DOB NOW: Build by a Licensed Master Plumber. We take care of the filing, approvals and sign-off.

Getting started

What information do you need to get started?

The property address, a contact person, and the services you’re asking about. If you have them, recent DOB or DEP notices, violation numbers and prior inspection reports help us move faster. Send it through our contact form or call 718.865.3779, and we’ll take it from there.

Can you take over a compliance issue that’s already in progress?

Yes. Send us the notices, violations or reports you’ve received and we’ll review where things stand and what comes next.

I smell gas. Should I contact Mainstream?

No — treat it as an emergency. Leave the building immediately and, from a safe location, call 911 and your gas utility. Contact us afterward and we’ll handle any follow-up compliance requirements.

Answers summarize NYC agency guidance as of November 2026 and are general information, not legal advice. Requirements change; contact us to confirm what applies to your property.

Still have a question?

Our team will give you a straight answer and take it from there.

718.865.3779
Image 02 · hero-gas-alarm.jpg

Local Law 157

Natural gas alarms are due January 1, 2027.

Covered residential buildings with gas service must have approved natural gas alarms installed by the deadline. Mainstream offers approved detectors at competitive pricing and can arrange installation.